Industrial processes produce a significant amount of heat, which must be dissipated to protect sensitive equipment and finished products. The use of chiller systems, which can be water or air-cooled, is a well-established method of monitoring and regulating temperatures at optimal levels. This article will differentiate a water-cooled chiller system from an air-cooled chiller system.
Air-cooled Chiller vs. Water-cooled Chiller
Although both air-cooled chillers and water-cooled chillers function to remove unwanted heat from manufacturing processes, they differ in many ways. Deciding which chiller type best suits your industrial application depends on several factors, such as:
- Chiller condenser mechanisms
- Water cooling vs. air cooling cost differences
- Chiller capacity ranges
- Environmental and location considerations
- Operational and aesthetic differences
A. Air-cooled Condenser vs. Water-cooled Condenser
There are distinct differences between the condenser of an air-cooled chiller and a water-cooled chiller. Air-cooled chillers are equipped with condensers that utilize ambient air to reduce refrigerant temperatures. Fans force the air over tubing containing refrigerant and therefore eliminate heat from it. The cooled refrigerant used in chillers can then be circulated through the industrial process to achieve a cooling effect.
By contrast, water-cooled chillers take advantage of the high heat capacity of water to facilitate refrigerant chilling. The typical coolant used in water-cooled systems is a mixture of water and chiller glycol, which is circulated in a sealed network of tubing. Cooling occurs when the chilled refrigerant is passed through a heat exchanger that interfaces with the industrial process. Warmed coolant is then returned to a cooling tower or refrigeration unit, eliminating acquired heat in preparation for another cooling cycle.
B. Capacity Range
Is water cooling better than air cooling when it comes to size? Air-cooled chillers come in sizes ranging from 2 – 40 tons. Meanwhile, water-cooled chillers offer a higher cooling capacity of 10 – 1,000 tons.
C. Environment/Location
The planned location of a chiller unit is another crucial point to consider when deciding on an industrial chiller. Again, depending on site plans, there are pros and cons to opting for air-cooled or water-cooled chillers.
● Indoor Locations
Both air-cooled and water-cooled chiller variants can be installed in an indoor location. However, additional space considerations must be made for air-cooled chillers. This is because air-cooled chillers require access to enough ambient air to function correctly.
Situating an air-cooled chiller in a poorly ventilated indoor space will hamper its cooling abilities and reduce efficiency. By comparison, water chillers can be installed in areas with minimal ventilation as their cooling towers can be placed on the building’s exterior.
● Outdoor Locations
Opting for an air-cooled chiller in an outdoor setting is advantageous as there is unlimited access to a high flow of the ambient air required to facilitate coolant chilling. Consequently, water-cooled chiller systems are seldom situated in an outdoor location.
D. Equipment Longevity
Water-cooled chilling systems have a lifespan of about 20 – 30 years. On the other hand, air-cooled units typically last 15 – 20 years.
The reason for this difference is that water-cooled chillers are usually installed inside and operate at lower condenser pressures, and outdoor air-cooled chillers operate at higher condenser pressures. Either way, proper commercial chiller repair can extend the life of your equipment, so don’t neglect it!
E. Chiller Efficiency
Which process is more efficient: water cooling or air cooling? By comparison, water-cooled chillers are more efficient than air-cooled variants. Air-cooled chiller efficiency is dependent on the temperature of the ambient air being used in its cooling system. The higher the circulating cooling air temperature, the less efficiently an air-cooled chiller will perform.
Overall, more energy will be expended to repeatedly pump air through the chiller heat exchanger to achieve the desired coolant temperatures.
Comparably, water-cooled chiller efficiency is much higher as they operate less dependently on ambient environmental air temperatures. In addition, utilizing water cooling towers or refrigeration units will ensure a steady regulation of chiller fluid within an optimal range. Therefore industrial processes using these chillers will be cooled appropriately.
F. Noise Level
Is there a difference between an all-air system and an all-water system when it comes to noise output? Yes. Outdoor air-cooled chillers are known to produce higher noise levels via chiller condenser fans. However, low-noise options are available with a sound-proof design and reduced fan rotation speed. This results in significantly lower sound pressure levels.
Contact Kingfit for Air-cooled Chillers and Water-cooled Chillers